These system specifications are recommendations for your DCO system configuration in general. The performance and operation of the system depends largely on the nature of the configuration, such as:
- Number and population of racks
- Number and nature of integrations to external systems
- Number of devices and number of data points stored on these
- Power path configuration (one big, several small, across rooms, etc.)
- Concurrent and total users of the system and nature of their work cycle
- Cluster configuration (recommended to run on hardware, not virtual setup for better ready time)
If StruxureWare Data Center Operation is running on lower specification servers than recommended, users may experience long response times or timeout issues. In addition, the server may not be able to process scheduled jobs in a timely manner. This can lead to an infinite job queue, where the amount of queued work on the StruxureWare Data Center Operation server is ever increasing to the point where one or more StruxureWare Data Center Operation cluster servers are no longer responsive.
Recommended server hardware for StruxureWare Data Center Operation
The StruxureWare Data Center Operation Suite requires a dedicated server, either hardware or a virtual environment. The operating system is included in the StruxureWare Data Center Operation installation. For further details, see here. The below requirements are referring to the latest version StruxureWare Data Center Operation.
Recommended StruxureWare Data Center Operation server configuration
Server requirement guidelines
- CPU: 4 cores minimum. We recommend 8 cores
- Memory: 16 GB RAM
- 100 GB storage, speed minimum 170 MB/s
- Cluster network: 1 Gbps connection between nodes
- Disaster recovery network: 10 Mbps with low latency <100 ms
Server requirement guidelines for 10,000 racks across 200 rooms with 30 concurrent users
- 8 CPU cores
- 32 GB RAM
- 1 Gbps network connection between cluster nodes
- 100 GB storage, speed minimum 170 MB/s
Server requirement guidelines for 20,000 racks across 400 rooms with 30 concurrent users
- 16 CPU cores
- 64 GB RAM
- 1 Gbps network connection between cluster nodes
- 100 GB storage, speed minimum 170 MB/s
RAID systems
Recommended: Hardware RAID controllers (we have tested hardware controllers in the following server series, DELL x20 series, IBM M4 series, HP G8 series) Be aware there might be hardware RAID controllers that we have not tested in special configuration of the server series mentioned.
Not supported:
Generally all software RAID controllers
HP RAID Controller B-Series
DELL RAID Controller S-Series
Security configuration
For information about security configuration, see here.
StruxureWare Data Center Operation Server Communication
For information on server communication, see here.
Recommended StruxureWare Data Center Operation Client Configuration
- Processor: 2 GHz Intel Core 2 Duo (or equivalent)
- Hard disk: 500 MB free hard disk space for installation
- Memory: 4 GB RAM
- Display: Absolute minimum 1024x768 screen resolution with 16 million colors, 1280x1024 is recommended. For 3D view to work, 3D hardware including working drivers are needed
- Operating System: MS Windows Vista, Windows 7, Windows 8, Windows 8.1, Mac OS X (Mountain Lion), Linux (supported Linux versions)
- Browser: Internet Explorer (v11 and newer), Chrome (all versions), and Firefox (all versions)
These are the absolute minimum recommendations for running StruxureWare Data Center Operation but for larger setups, better specifications are recommended.
You must have local administration rights on the client computer during installation, first login, and license upgrade.
See also |
---|
StruxureWare Portal System Requirements
IT Optimize Server Requirements
IT Optimize Client Requirements
StruxureWare Data Center Operation Security
StruxureWare Data Center Operation Network Firewall Port Details
Installing StruxureWare Data Center Operation
Troubleshooting Performance Issues
Configuring External System Integration
StruxureWare Portal v.1.2
Installing IT Optimize
Initial Setup of StruxureWare Data Center Operation PRO Pack