You may want to change some default settings of the DCO web client, e.g. if you want to brand your site with your own logo, or color.

These settings are available in the branding folder on your DCO server and can be changed through the server management interface (Webmin).

Replacing the icon will change the icon you see on login as well as the small icon in the top left corner of the web client.

Regardless of your image size, it will be automatically scaled to fit into the position of the default image. However, it's recommended to use a photo in a square shape for the logo.png file.

  1. Rename your custom file(s)
    1. background image --> bg_login.jpg.
    2. logo --> logo.png
    3. company logo --> company_logo.png
  2. Open the server management web interface (Webmin) by typing the address of your DCO server in a web browser folllowed by :10000, https://<server IP address>:10000 .
  3. Log on to Webmin using the user credentials created during the server installation.
  4. In the left menu, select System>Upload and Download.
  5. On the Upload to server tab: 
    1. Click Choose Files in Files to upload and navigate to your saved bg_login.jpg file. Same procedure for logo.png file and company_logo.png file.
    2. In File or directory to upload to navigate to the branding folder on your server:
      • 8.0 - 8.0.3 - /opt/jboss-as/standalone/deployments/webclient.war/web/client/css/branding.
      • 8.0.4+ - /opt/jboss-as/standalone/deployments/webclient.war/web/resources/branding.
    3. In Owned by user and Owned by group, select dcojboss.
    4. Click Upload.
  6. Close and reopen your web browser and type the server address to access the login screen with your new custom images.

Changing website color theme

The color theme determines the color of borders in the web client (default green), e.g. borders of dialog boxes, borders in license icons, borders in room icons in the inventory, etc.

  1. Open and log in to Webmin as described above and navigate to  System>Upload and Download in the left menu.
  2. On the Download from server tab, navigate to the branding folder on your server:
    • 8.0 - 8.0.3 - /opt/jboss-as/standalone/deployments/webclient.war/web/client/css/branding.
    • 8.0.4+ - /opt/jboss-as/standalone/deployments/webclient.war/web/resources/branding.
    and download the branding.css file.
  3. Open the branding.css file, make your changes to the color codes, and save the file.
    Tip: You can find an introduction to HEX color codes here: http://www.w3schools.com/cssref/css_colors.asp.  
  4. Reopen the Webmin interface and navigate to System>Upload and Download.
  5. On the Upload to server tab: 
    1. Click Choose Files in Files to upload and navigate to your saved branding.css file.
    2. In File or directory to upload to navigate to the branding folder on your server:
      • 8.0 - 8.0.3 - /opt/jboss-as/standalone/deployments/webclient.war/web/client/css/branding.
      • 8.0.4+ - /opt/jboss-as/standalone/deployments/webclient.war/web/resources/branding.
    3. In Owned by user and Owned by group, select dcojboss.
    4. Click Upload.
    5. Close and reopen your web browser and type the server address to log in to the web client with your custom color theme.

 

 

 

The default help link goes to our support and help site. To redirect to your custom help site, change the settings in the branding.json file.

  1. Open and log in to Webmin as described above and navigate to System>Upload and Download in the left menu.
  2. On the Download from server tab, navigate to the branding folder on your server:
    • 8.0 - 8.0.3 - /opt/jboss-as/standalone/deployments/webclient.war/web/client/css/branding.
    • 8.0.4+ - /opt/jboss-as/standalone/deployments/webclient.war/web/resources/branding.
    and download the branding.json file.
  3. Open the branding.json file, make your changes to the link, and save the file.
    {
       "subTitle": "StruxureWare",
       "title": "Data Center Operation",
       "helpUrl": " http://sxwhelpcenter.ecostruxureit.com ",
       "tenantPortalUrl": ""
    }
     
  4. Reopen the Webmin interface and navigate to System>Upload and Download.
  5. On the Upload to server tab: 
    1. Click Choose Files in Files to upload and navigate to your saved branding.json file.
    2. In File or directory to upload to navigate to the branding folder on your server:
      • 8.0 - 8.0.3 - /opt/jboss-as/standalone/deployments/webclient.war/web/client/css/branding.
      • 8.0.4+ - /opt/jboss-as/standalone/deployments/webclient.war/web/resources/branding.
    3. In Owned by user and Owned by group, select dcojboss.
    4. Click Upload.
    5. Close and reopen your web browser and type the server address to log in to the web client with your custom help link.

 

 

 