Our Data Center Expert DDF repository contains the most commonly requested DDFs.
New third party DDFs for assets from manufacturers that are not included in your active DCE software support contract can only be added through the Asset Definition service.
You can use this service to request up to 20 DDFs to be delivered to you at a pre-determined time. More...
To request a DDF:
Go to https://ddf.ecostruxureit.com/ and search for the device. A DDF might already be available.
If a DDF is not available, click contact support at the botom of the page or use this form to submit a request.
To troubleshoot devices or to create DCE DDFs, an output of a device's addresses and their values is necessary. This page describes how to generate that output for SNMP, Modbus, and NetBotz devices.
SNMP for DCE version 7.6 and newer
Log in to the DCE web client, version DCE 7.6. and newer.
Click Status in the menu in the upper right corner of the page.
Under Additional Information, select SNMP Device Walk and click Submit.
In the Target Host field, enter the IP address of the device you want to walk.
Select SNMPv1 or v3 and enter the credentials. Hint: If using SNMPv1, the default Read Community on most devices is public.
Click Submit.
DCE_SNMP_device_walk_2_360006388878.png
It takes a few minutes to process. Wait for the spinner to stop.
The results will be printed on the page.
In the browser, select File > Save As, or copy and paste the text to a text file.
Save the file and send it to the DDF Team in an Asset Definition Request, or as requested by technical support.
For Modbus on any DCE version
or SNMP with DCE versions prior to 7.6
Modbus.org announced it is expunging all occurrences of inappropriate language of the query and response paradigm of Modbus communications. This tool was updated to comply as of version 1.9.1. More...
Requirements
Windows 10+ or Windows Server 2012+
Admin access to Command Line or Windows PowerShell
Download the walk utility from here.
Unzip the file.
Open and read the README.txt file for detailed instructions on how to use the command line utility. See information about general usage here.
Open a Command Prompt (Admin) or Windows PowerShell (Admin) and navigate to the folder you just unzipped.
Run: walk.bat <protocol> -ip <ip> <options>
This will generate a walk file named using the IP Address and a ".walk", ".json", or ".xml" extension.
Hey there! It's nice to see you here!
Our mission is to give you the best support possible. That's why we moved the help center closer to the EcoStruxure IT Community.
You'll find articles here about EcoStruxure IT Expert, including the Gateway and the EcoStruxure IT mobile app, IT Advisor, Data Center Expert, NetBotz, Asset Advisor, and more.
Click the link in the upper right to sign in using your Scheinder Electric account. Don't have an account? You can register any time you visit.
Are you looking for the support community? Visit the EcoStruxure IT forum.
All the important knowledge you’ve provided over the years is right here.
We hope you enjoy using the EcoStruxure IT Community, both the Help Center and the Forum. Click the Feedback button on the right and let us know what you think - we love hearing from you!
Processing power, CPU utilization, and available system memory have the biggest impact on sensor loading time at login.
The best results are seen with the i7 chipset with multiple cores. Connecting to DCE via HTTP or HTTPS has minimal impact on loading time.
Although the primary focus is specific to DCE run on a physical server, this information technically applies to DCE virtual machines also.
Windows
Chipset
OS
Memory
Sensor count
Login time (Avg)
Client CPU activity
i7-7820HQ 2.90GHz
Windows 10
32GB
10,000
00:00:04
15%
i7-7820HQ 2.90GHz
Windows 10
32GB
141,000
00:00:25
15%
i7-6820HQ 2.71GHz
Windows 10
16GB
264,000
00:01:24
20%
i7-7820HQ 2.90GHz
Windows 10
32GB
264,000
00:01:36
15%
i7-7600U 2.80GHz
Windows 10
16GB
264,000
00:02:05
20%
i7-4600m
Windows 10
8GB
264,000
00:02:05
10%
i5-4300U 1.9GHz
Windows 7
16GB
264,000
00:04:06
70%
T9300 2.50GHz
Windows 7
4GB
264,000
00:04:34
10%
T9300 2.50GHz
Windows 7
4GB
264,000
00:04:42
10%
M-5Y71 1.2GHZ
Windows 8
4GB
264,000
00:06:15
60%
This issue was addressed in DCE 8.0.
EcoStruxure IT Data Center Expert 8.0 release notes
Changing some system settings or using the File > Change Server option in the Data Center Expert client causes DCE to restart. In DCE 7.7.1 and newer, the client launcher does not reopen after DCE restarts to allow you to log in again.
In DCE 7.9.3, the desktop shortcut created by the installer includes the -h parameter in the Target path to restore this functionality. The executable in the installation directory does not include this parameter. If you want to create a shortcut from the executable in the installation directory, you must add the -h parameter to the Target path:
Go to the dcexpert folder in the DCE installation directory. Example: C:\Program Files\StruxureWare Data Center Expert 7.9.3\dcexpert.
Right click and select Create shortcut.
Right click the shortcut, select Properties, and then select the Shortcut tab.
Add -h to the end of the Target path after the end quotation.
Click Apply.
8691473775005_8131873168029.png
The DCE server upgrade progress displayed in the web client during the upgrade from DCE 7.9.3 to version 8.0 does not accurately represent the process. The upgrade completes successfully.
This will be addressed in the next release.
11302874552093_11302746112925.png
You can change the protocol only on APC SNMPv1 devices that support SNMPv3. For information about whether an APC SNMP device supports SNMPv3, consult the device documentation.
Before you begin, it is recommended you view and confirm the devices you want to convert from SNMPv1 to SNMPv3 in the "Device Scan Settings" display, accessed from the SNMP Device Communication Settings option in the Device menu.
Select the APC SNMP Device Configuration option in the Device menu.
Select Configure Devices.
Select the APC SNMPv3 device you want to use as the source.
Click Retrieve Device Settings.
Click Next to select the devices you want to convert to SNMPv3.
To ensure only the devices you want to convert to SNMPv3 are selected, you can checkmark Select/Deselect All to clear the list, then checkmark the devices to include.
Expand SNMPv1 Settings and checkmark the Access option.
Double-click the Access option under SNMPv1 Settings, or select the Access option and click Edit, to change its setting to Disabled, if necessary.
Uncheck Authentication options 1 - 4, if necessary.
Expand the SNMPv3 Settings option.
Double-click the Access option under SNMPv3 Settings, or select the Access option and click Edit, to change its setting to Enabled, if necessary.
Expand the Authentication options 1 - 4 you want to use, select the Access option under each option, and click Edit, to change its setting to Enabled, if necessary.
Checkmark other available options to change their settings, if necessary.
The security settings on some target devices might require setting user passwords, authentication phrases, and encryption phrases manually at the device user interface.
Click Finish.
You can monitor progress applying the settings to the selected devices in the Device Configuration Status view, accessed from the Device option in the Window menu.
In DCE 7.6.0 and higher, you can change the IP address of a discovered device without losing any data.
After you change the IP address on the Network Management Card:
Go to the Device > SNMP Device Communication Settings > Device Scan Settings option.
Select a device, then select Edit Device Scan Settings.
Change the IP address listed there.
138808999_542x400_360038795414.png
Access to customer support for this or any other APC product is available from virtually anywhere in the world.
To access documents in the APC Knowledge Base, to submit customer support requests, or to locate the telephone number for the support you need, please do the following:
Go to the APC Support page: http://www.apc.com/support.
Select the appropriate country from the Country drop-down menu at the top of the page, and do any of the following:
Use the available links to access web-based support, including links to a full range of self-help documents, and the APC Knowledge Base.
Use the Phone support link under Ask APC in the left side of the page to access country-specific address, phone, and e-mail information.
You can also contact the APC representative or other distributor from whom you purchased your APC product for information on how to obtain local customer support.
Some devices, including many Uniflair cooling devices, use a network card from Carel called pCOWeb. These cards can be problematic for Data Center Expert because the type of device they are installed in is not identified, and the same SNMP addresses (OIDs) are used to represent different things.
DCE cannot automatically choose the correct DDF for devices with pCOWeb network cards. If you only have one DDF installed to support devices that use the pCOWeb card, it's not a problem.
If you need multiple DDFs to support devices that use the pCOWeb card, you must configure the card to provide identifying information and modify the DDF to look for that information.
To configure the pCOWeb card:
Follow the instructions on page 35 of the pCOWeb User Manual to change the value of the system name at OID 1.3.6.1.2.1.1.5. The name should identify the DDF to use, for example, amico_leonardo_ug40mp40.
To modify the DDF:
Open the DDF in a text editor and find this line (note that the xxxxxx will vary between DDFs:
<oidMustExist ruleid="xxxxxx" oid=".1.3.6.1.4.1.9839.2.1" istree="yes" />
Insert the following lines immediate after the line above, but replace xxxxxx with the name you created in the first step:
<oidMustMatch ruleid="sysname" oid=".1.3.6.1.2.1.1.5.0"> <valueList> <value>xxxxxx</value> </valueList> </oidMustMatch>
Device Definition Files (DDF) were updated in Data Center Expert 7.4.3 to address a recently discovered issue in Data Center Expert v7.4.0, v7.4.1, and v7.4.2. Earlier Data Center Expert versions are not affected.
Affected devices have duplicate sensor entries in Data Center Expert, with sensor status reported as unplugged.
The values for the following sensors could not be corrected, causing some sensors to report as unplugged in DCE 7.4.3.
You can delete the unplugged sensors, but historical sensor data will be lost. Otherwise, you can leave the sensor in the unplugged state to maintain historical data. Contact your local technical support if you have questions about a specific sensor value.
Sensor
Model affected*
Number of External Battery Packs
Smart-UPS 1500/3000
Battery Current
Symmetra PX 250/500 and Galaxy VM/VX 3-phase UPS
(Main/Bypass) Input Apparent Power - Phase (1-3)
Symmetra PX 250/500 and Galaxy VM/VX 3-phase UPS
(Main/Bypass) Input Power - Phase (1-3)
Symmetra PX 250/500 and Galaxy VM/VX 3-phase UPS
(Main/Bypass) Input Current Phase - (1-3)
Smart-UPS VT/RT, Symmetra PX, Silcon and Galaxy 3-phase UPS
(Main/Bypass) Input Apparent Power Total
Symmetra PX, Symmetra 250/500 UPS, and Silcon UPS
Output Power VA - Phase (1-3)
Smart-UPS VT/RT, Symmetra PX, Silcon and Galaxy 3-phase UPS
Output Peak Current - Phase (1-3)
Galaxy VM/VX UPS
Output Current THD - Phase (1-3)
Galaxy VM/VX UPS
Input Peak Current Phase - (1-3)
Galaxy VM/VX UPS
Output Power Watts - Phase (1-3)
Symmetra PX 250/500 and Galaxy VM/VX 3-phase UPS
Battery Type
Galaxy VM 180/200 UPS
Battery Status
Single phase Smart-UPS and Matrix UPS
*Other models may be affected.
This table will help you accurately identify the appropriate DDF for any Uniflair model.
Only one Carel pCOWeb SNMP DDF can be installed per DCE server regardless of vendor.
See Carel pCOWeb cards for more information.
NOTE: An asterisk (*) in the Device Family/SKU name indicates a wildcard value, for example, TRAF1221A1 and TRAC4042A1 would both fall under "TR******A (last letter is A).
NOTE: pCO5 and pCO5+ are different controllers.
Modbus
File Name
Device Family/SKU
Controller/Interface
uniflair_am_uniflair_le_amico_leonardo_ug40mp40_TCPIP_Modbus_CCU
pCO1/UG40
Uniflair LE: TDCR, TUCR, TDCV, TUCV, IDAV, TDAR, TDDR, TDDV, TDER, TDTR,
TDTV, TDWR, TUAR, TUDR, TUDV, TUER, TUTR, TUTV, TUWR, TDAV, TDEV, TDWV, TUAV, TUEV, TUWV
Uniflair AM: SDA, SDC, SDW, SUA, SUC, SUW
uniflair_am_uniflair_le_amico_leonardo_ug50_TCPIP_Modbus_CCU
pCO5+/UG50
Uniflair LE: HDCV, HDCV5000D, HDCV5000L
uniflair_aquacentr_TCPIP_Modbus_chiller_imperial (imperial units only)
BCE*, BCW*
NOTE: pCO controller determines the correct DDF to use. Controller MUST match
pCO5+/UG50
uniflair_aquascrew_TCPIP_Modbus_chiller
BRE*
NOTE: pCO controller determines the correct DDF to use. Controller MUST match
pCO5+/UG50
uniflair_aquascroll_TCPIP_Modbus_chiller
ERAC, ERAH, ERAF, ERCC, ERCH, ERCF
ISAC, ISAH, ISAF, ISCC, ISCH, ISCF
TR******A (last letter is A)
NOTE: Aquascroll Firmware
pCO5+/UG50
uniflair_aranew_TCPIP_Modbus_chiller
ARAC, ARAH, ARAF
pCO1/MP20II
uniflair_bce_TCPIP_Modbus_chiller
BCE*
NOTE: pCO controller determines the correct DDF to use. Controller MUST match
pCO5/UG50
uniflair_bcwc_TCPIP_Modbus_chiller
BCW*
NOTE: pCO controller determines the correct DDF to use. Controller MUST match
pCO3/UG50
uniflair_bra_TCPIP_Modbus_chiller
BRA*
pCO1/MP20II
uniflair_bref_TCPIP_Modbus_chiller
BRE*
NOTE: pCO controller determines the correct DDF to use. Controller MUST match.
pCO1/MP20II
uniflair_brwc_TCPIP_Modbus_chiller
BRR*, BRW*
pCO1/MP20II
uniflair_era_TCPIP_Modbus_chiller
ERAC, ERAH, ERAF, ERCC, ERCH, ERCF
NOTE: pCO controller and firmware determine the correct DDF to use. They MUST match.
NOTE: Does NOT use Aquascroll Firmware
pCO1/MP20II
uniflair_isa_TCPIP_Modbus_chiller
ISAC, ISAH, ISAF, ISCC, ISCH, ISCF
NOTE: pCO controller and firmware determine the correct DDF to use. They MUST match.
NOTE: Does NOT use Aquascroll Firmware
pCO1/MP20II
uniflair_lra_TCPIP_Modbus_chiller
LRAC, LRAH
pCOXS/-
uniflair_sp_uniflair_wm_uniflair_mb_telnew_TCPIP_Modbus_CCU
UCA* , UCF*, UWA*, UWF*,WDA*, WDF*, WMA*, WMF*,XDA* , XDF*, (ADD*/ XDD* displacement units), XMA*, XMF*
pCO1/UG40
uniflair_tra_TCPIP_Modbus_chiller
TR******A (last letter is A)
NOTE: TRA 1.x Firmware
pCO5+/UG50
SNMP
NOTE: Any file name with a leading asterisk (*) is included with a DCE installation.
NOTE: File names that are bold are considered pCOWeb SNMP DDFs as mentioned at the top of this article.
File Name
Device Family/SKU
Controller/Interface
*apc_acrd2g
ACRC60xx, ACRD60x
Schneider C3P (R2)/Touch (4.3")
apc_air_economizer
IAEC25, IAEC50
Schneider J5-18DIN/Touch (7")
*apcacirg2
ACRD10x, ACRD20x
Schneider C3P (mR1)/PowerView
*apcacsc
ACSC10x
Schneider C3P (mR1)/PowerView
*apcraru
ACF40x
Schneider ARU (mR1)/PowerView
*schneider_acrc301s
ACRC30xx
Schneider J5-13DIN/Touch (4.3")
*schneiderelectric_ledxg2
LD*V* / IX*V* / I**V*
Schneider J5-18DIN/Touch (7")
schneiderelectric_tsatra
TSA*, TR******A1 (last characters are A1)
pCO5+/Touch (7")
uniflair_am_uniflair_le_amico_leonardo_ug40mp40_SNMP_CCU
Uniflair LE: TDCR, TUCR, TDCV, TUCV, IDAV, TDAR, TDDR, TDDV, TDER, TDTR,
TDTV, TDWR, TUAR, TUDR, TUDV, TUER, TUTR, TUTV, TUWR, TDAV, TDEV, TDWV, TUAV, TUEV, TUWV
Uniflair AM: SDA, SDC, SDW, SUA, SUC, SUW
pCO1/UG40
uniflair_am_uniflair_le_amico_leonardo_ug50mp50_SNMP_CCU
Uniflair LE: HDCV, HDCV5000D, HDCV5000L
pCO5+/UG50
uniflair_aquacentr_SNMP_chiller_imperial (imperial units only)
BCE*, BCW*
NOTE: pCO controller determines the correct DDF to use. Controller MUST match
pCO5+/UG50
uniflair_aquascrew_SNMP_chiller
BRE*
NOTE: pCO controller determines the correct DDF to use. Controller MUST match
pCO5+/UG50
uniflair_aquascroll_SNMP_chiller
ERAC, ERAH, ERAF, ERCC, ERCH, ERCF
ISAC, ISAH, ISAF, ISCC, ISCH, ISCF
TR******A (last letter is A)
NOTE: Aquascroll Firmware
pCO5+/UG50
uniflair_aranew_SNMP_chiller
ARAC, ARAH, ARAF
pCO1/MP20II
uniflair_bce_SNMP_chiller (metric units only)
BCE*
NOTE: pCO controller determines the correct DDF to use. Controller MUST match
pCO5/UG50
uniflair_bra_SNMP_chiller
BRA*
pCO1/MP20II
uniflair_bref_SNMP_chiller
BRE*
NOTE: pCO controller determines the correct DDF to use. Controller MUST match
pCO1/MP20II
uniflair_brwc_SNMP_chiller
BRR*, BRW*
pCO1/MP20II
uniflair_era_SNMP_chiller
ERAC, ERAH, ERAF, ERCC, ERCH, ERCF
NOTE: pCO controller and firmware determine the correct DDF to use. They MUST match
NOTE: Does NOT use Aquascroll Firmware
pCO1/MP20II
uniflair_isa_SNMP_chiller
ISAC, ISAH, ISAF, ISCC, ISCH, ISCF
NOTE: pCO controller and firmware determine the correct DDF to use. They MUST match
NOTE: Does NOT use Aquascroll Firmware
pCO1/MP20II
*uniflair_le_ddf
T*C* (third letter "C")
HDCV*
T*AG, T*DG, T*WG, T*TG, T*EG, (last letter G)
NOTE: pCO controller determines the correct DDF to use. Controller MUST match
pCO5+/Touch (7")
Uniflair_LEL
LDCV*
pCO5+/Touch (7")
uniflair_lra_SNMP_chiller
LRAC, LRAH
pCOXS/-
uniflair_sp_uniflair_wm_uniflair_mb_telnew_SNMP_CCU
UCA* , UCF*, UWA*, UWF*,WDA*, WDF*, WMA*, WMF*,XDA* , XDF*, (ADD*/ XDD* displacement units), XMA*, XMF*
pCO1/UG40
uniflair_trac_SNMP_chiller
TR******A (last letter is A)
NOTE: TRA 1.x Firmware
pCO5+/UG50
Device status may be inaccurate because an attempt to transfer a device definition file (DDF) failed
If you have followed the instructions in NetBotz 750 appliance discovery process in DCE and the error has not cleared:
Ping from the DCE server to the NetBotz 750.
If ping fails, allow or enable ICMP in your firewall from the DCE server IP address to the NetBotz 750 IP address.
You might need to rediscover the device in DCE.
For best results, update your DCE and NetBotz 750 to the latest versions.
In DCE 7.9.0 and newer, the Launch to Device option does not work for NMC 1 devices that use HTTPS on the DCE private network. Connect a computer to the DCE private network to directly access the device's web user interface.
NMC 1 does not support SSL protocols more recent than TLS 1.0. Updated security policies introduced in DCE 7.9.0 do not include TLS 1.0. The option to choose between TLS versions was removed from DCE for security reasons.
Sensor information, alarms, alarm notification, graphing, etc. for NMC 1 devices are not affected since they do not rely on web functionality.
This applies to devices with NMC 1 (AP9617, AP9618, AP9619) and devices with an embedded NMC 1 including, but not limited to: Metered/Switched Rack PDUs (AP78XX, AP79XX); Rack Automatic Transfer Switches (AP77XX); Environmental Monitoring Units (AP9320, AP9340, NetBotz 200).
See Known issues in DCE
Verify the Data Center Expert installer MD5 or SHA1 checksum on a Windows or Linux computer before you use it to perform a software update.
DO NOT run the installer if your calculated value does not match the published checksum for your DCE version and operating system.
Verify from Windows PowerShell
Download the Data Center Expert upgrade.zip file to your Windows machine.
Open PowerShell. The PowerShell.exe command starts a session in a command window.
Navigate to the directory containing the downloaded .zip file.
Use the Get-FileHash PowerShell command to calculate the SHA1 or MD5 checksum of the file and compare it against the published value in the table. Get-FileHash -Path .\upgrade-xxx.xx.zip -Algorithm SHA1 Get-FileHash -Path .\upgrade-xx.xx.zip -Algorithm MD5
Verify from a Linux terminal
Download the Data Center Expert upgrade.zip file to your CentOS or RHEL machine.
Open a terminal window.
Navigate to the directory containing the downloaded .zip file.
Use the sha1sum or md5sum terminal command to calculate the SHA1 or MD5 checksum of the installer and compare it against the published value. sha1sum upgrade.zip md5sum upgrade.zip
See Complete update process for DCE
Before requesting support for a device, verify that it doesn't already exist in the system.
Search for existing DDFs
Type the device details in the search box on the DCIM Support help center's DDF page here.
DCIMHC_DDF_option_360006358437.PNG
Verify whether the device exists in your installation of DCE
In the Data Center Expert Device menu, the Modbus Device Communication Settings > Device Definition Files option and the SNMP Device Communication Settings > Device Definition Files option list the Modbus or SNMP DDFs already installed on the DCE server.
Hello!
It's nice to see you here! Welcome to the EcoStruxure IT Help Center!
Check out the EcoStruxure IT Expert demo
This read-only self-service demo is based on a real organization with real data that demonstrates IT Expert functionality in a preconfigured environment - no signup required! More info
WARNING: This process requires a reboot of the appliance. The appliance will not collect any data from devices, including alarms that may occur, until the system comes back up after the reboot.
If multiple users use the system, you may want to notify them that the system will be rebooted in order to perform the steps listed below.
For physical appliances, connect a keyboard and monitor to the appliance. For virtual appliances, connect to the console.
Reboot the DCE server by power cycling the physical appliance or virtual appliance.
For DCE 7.7.x and older, log in within 5 minutes of rebooting with the following credentials: Username: apcreset Password: apc
For DCE 7.8.0 and newer, log in within 5 minutes of rebooting with the following credentials: Username: apcreset Password: Use the password you set when you first deployed the DCE server. This was required in DCE 7.8.0 and newer to comply with California law. See DCE 7.8.0 release notes
Follow the instructions when prompted to reset the apc admin user to factory defaults (apc/apc). NOTE: This will not reset the whole appliance to defaults, only the username and password for the default admin user.
Log in to the DCE desktop client with the factory default username and password apc/apc.
Go to System > Users and Device Group Access. Select the apc user and then select Edit to change the password.
If you experience any issues during this process, contact your local technical support.